Tsunami-1000

Large-scale atmospheric water generator, aimed for fast and easy deployment. Non-complex operation.

Suitable for continual or backup water supply for homes and various other facilities; disaster relief projects; farms & ranches; marine environment: military ships, cruise ships; construction sites; remote armed forces camps; remote oil, gas and mineral exploration camps; water bottling plants etc.

Water production rate:

up to 480 gal (1800 L) per day


Physical dimensions: 6' x 9' x 90" / 1.8 x 2.8 x 2.3 m (W x L x H)


Power source: Power Grid (1- or 3-phase, 200-230V AC / 380V AC / 400-480V AC) / 15KW generator with insulated enclosure, fueled by diesel / Solar system.


Working conditions: temperature 50-115°F / 10-45°C, relative humidity 30-100%.


Renewable & Eco-friendly

Atmospheric water generation taps into nature's water cycle, mimicking conditions inside a cloud.

Ultra-pure & Delicious Water

Multi-stage filtration process produces supreme quality drinking water.

Plug & Use

No assembly required. All single container units are 100% turnkey and delivered ready-for-use.

Self-contained & Weatherproof

Custom-designed shelter protects from exposure to ambient conditions & unauthorized access.

Transportable

Moved around with a forklift or crane truck. Can be towed (with optional plug axles & tow hitch) or airlifted, and set at any location.

1-year Standard Warranty

Conditions apply. Extended warranty available upon request.

20+ Years Lifespan

Only high-quality parts and materials used. The unit is built to last & requires extremely low maintenance.

Potential Water Yields

The below graphs give a representation of the expected water yields based on temperature and relative humidity. These are merely guidelines as humidity and temperature vary constantly throughout the day.

Production rate of the unit shown on the web-site is based on the yield at 86°F / 30°C and 85% relative humidity.

Gallons per day

t°C/°F, RH 30% 35% 40% 45% 50% 55% 60% 65% 70% 75% 80% 85% 90%
+40°C
104°F
178 224 268 318 365 466 562 616 665 719 770 827 880
+35°C
95°F
137 171 203 242 278 355 429 469 507 548 588 631 671
+30°C
86°F
103 129 153 187 210 293 323 353 383 413 444 480 507
+25°C
77°F
77 96 114 138 156 217 239 262 284 306 329 351 376
+20°C
68°F
57 71 84 102 115 160 176 192 208 225 241 257 277
t°C/°F, RH +20°C
68°F
+25°C
77°F
+30°C
86°F
+35°C
95°F
+40°C
104°F
30% 57 77 103 137 178
35% 71 96 129 171 224
40% 84 114 153 203 268
45% 102 138 187 242 318
50% 115 156 210 278 365
55% 160 217 293 355 466
60% 176 239 323 429 562
65% 192 262 353 469 616
70% 208 284 383 507 665
75% 225 306 413 548 719
80% 241 329 444 588 770
85% 257 351 480 631 827
90% 277 376 507 671 880

Liters per day

t°C/°F, RH 30% 35% 40% 45% 50% 55% 60% 65% 70% 75% 80% 85% 90%
+40°C
104°F
674 849 1016 1202 1382 1762 2126 2330 2517 2720 2915 3130 3329
+35°C
95°F
518 647 770 915 1053 1345 1623 1776 1918 2076 2225 2390 2538
+30°C
86°F
391 487 578 707 796 1108 1222 1336 1451 1565 1680 1817 1919
+25°C
77°F
292 363 430 524 590 822 906 990 1074 1159 1244 1330 1423
+20°C
68°F
217 268 317 386 434 605 667 727 788 850 912 973 1048
t°C/°F, RH +20°C
68°F
+25°C
77°F
+30°C
86°F
+35°C
95°F
+40°C
104°F
30% 217 292 391 518 674
35% 268 363 487 647 849
40% 317 430 578 770 1016
45% 386 524 707 915 1202
50% 434 590 796 1053 1382
55% 605 822 1108 1345 1762
60% 667 906 1222 1623 2126
65% 727 990 1336 1776 2330
70% 788 1074 1451 1918 2517
75% 850 1159 1565 2076 2720
80% 912 1244 1680 2225 2915
85% 973 1330 1817 2390 3130
90% 1048 1423 1919 2538 3329

Tsunami-1000 Specifications

Water Production

Average: 10 US Gal/Hr (38 L/Hr)*

Maximum: 20+ US Gal (75+ L) per hour potential in higher ambient temperature and RH.

*Estimated at 70°F / 21°C and a relative humidity (RH) of 65%.
As ambient temperature and RH increase, so does water production.
Internal Water Storage Capacity 40 US Gal (150 L)
Air Filtration High efficiency multi layer Poly-fiber — washable & reusable
Water Filtration Multi stage: polypropylene, charcoal, Ultra Violet light
Refrigeration System
Refrigerant R410 (Standard)
(various options available for special requirements)
Compressors (2) x 5 ton, Scroll
Rated Voltage AC 230/(380) Volts ±10%
Frequency, Hz 50/60 Hz
Phase 1 PH (3 PH optional)
Amperage Range @ rated voltage

Startup current: 125 Amps (for 2-3 seconds)

Run current range: 30 to 50 Amps (dependent on ambient temperature)

Min Breaker: (2) @ 40 Amps (2-pole or 3-pole — depending on 1- or 3-phase)
Weights and Measurements
Physical dimensions, W x L x H 6' x 9' x 90" (1.8 x 2.8 x 2.3 m)
Weight (when empty) 3800 lb (1700 kg)
Optional Power Generator
Engine Driven Perkins (or similar) Liquid Cooled
Fuel Type Diesel
KW Output 15
Phase 1 PH or 3 PH
Voltage AC 208-230 VAC
380 VAC (optional)
Frequency, Hz 50/60 Hz
Fuel Consumption Average (Based on 75% Load) 1.3 US Gal/Hr (4.92 L/Hr)
Fuel Tank Capacity 200 US Gal (740 L)

Water production rates and other characteristics are subject to change as we make improvements in the design.

Applications

Drought or shortage of water
Drought or shortage of water
Disaster relief projects
Disaster relief projects
Marine environment: military ships, cruise ships
Marine environment: military ships, cruise ships
Construction sites
Construction sites
Remote armed forces camps
Remote armed forces camps
Remote oil, gas and mineral exploration camps
Remote oil, gas and mineral exploration camps
Water supply for various facilities
Water supply for various facilities
Water bottling plants
Water bottling plants

You might also be interested in:

Tsunami Products provides reliable, sustainable & cost-effective solutions to the world's growing water shortage.